Smoke Pipe M - Series

Smoke Pipe

M - Series

Steam Generators
DOWNLOAD CATALOG

Fully Safe, Vertical Design with Flame Smoke Pipe, designed for Medium Capacity (150-1,000 kg/h) and High Pressure (4-8 bar) steam generation.

High Efficiency Working System. (Efficiency:>91.5% avg. Flue Gas Temp.:<250⁰C, NOx:<60 ppm.)

Low Water Volume Design with no risk of explosion damage (death etc.). “97/23EC Category III&IV: V(lt.)*P(bar)<3,000”

Heavy Duty Body Construction designed for P quality sheet and pipe use in accordance with international norms (97/23EC).

PLC Control Module where all process parameters can be monitored and controlled precisely.

Double Stage or Modulation (50-100%) Operating System provided with the control of temperature and pressure parameters.

Proportional Controlled Beck Type Burner Group (Flam etc.)

Control Panel in accordance with the norms where the command/control fixtures (Schnedier, Omron, etc.) selected in accordance with international standards are collected.

Digital Error Indicator that checks negative external factors (water cut, chimney clogging, etc.).

Fail Proof Design in which Control and Safety Elements (Pressure Switches, Pressure and Temperature Transmitters, Safety Valve, Pump) are used with redundancy.

Jacketed Body design in which the flame dome pipes are embedded, providing a high heat transfer surface at low water volumes.

External Fan Module that provides forced flow by controlling the combustion air.

Multiple Flame Smoke Pipe bundle that minimizes thermal stresses by increasing the heat transfer surface in the combustion chamber.

Energy Saving with short (˂12-15 min.) start time due to low water volume.

Proportional Controlled Pneumatic Outlet Valve Module option designed to prevent pressure drop in peak drafts.

Pneumatic Start Valve Group, which allows the system to enter the regime automatically at the start of work.

Stop Solenoid Valve Group, which enables the system to be closed by performing the automatic Bottom Blowdown process at the end of the work.

Body-bound Steam Tub that controls the feed water level and process temperatures.

Inline type Vertical Feed Water Pump with high pressure, conforming to international standards (Grundfos etc.).

Possibility of adding electronic Steam, Water, Gas Flowmeter to the system to monitor operation consumptions.

Possibility to add electronic Conductivity, Hardness and pH Control Module to control system inputs.

TSEK, TUV Quality Certificates. Gazmer Certificate of Approval.


Unparalleled Process Monitoring and Ease of Use provided by the use of high-capacity CPU and 7” Touch Screen
Redundant Control and Protection Armatures for Maximum Safety (Triple Pressostat Group, Double Temperature Probe, Pressure Transmitter, Explosion Cap against Gas Compression.
Super Control Scheme that provides control and monitoring of all process inputs by measuring automatically. (Steam Flow, Water Consumption, Gas Consumption Measurements. Conductivity, Hardness and pH Measurement Control options.)
High Efficiency and Fully Saturated Steam Quality, provided with a higher (+30%) Heat Transfer Surface compared to its competitors, by using the Furnace Surface and Flame Smoke Pipes together.
Very short Start-Up Time, Low Bottom Blowdown Losses and Compliance with Safety Norms provided by the minimum water volume used between the Double Jackets.

M150 Specifications
Steam Capacity (Tsu:100°C.)
150
kg/sa.
Steam Heat Power
87.000
kcal/sa.
Steam Heat Power
101
kWh.
Steam Operating Pressure
6,0-8,0
bar.
Burner Power
112-140
kW.
Fuel Consumption(NG-LNG-LPG)
111
kWh.
Unit Water Volume
90
It.
Steam Connection
R1''
inch.
Exhaust Connection
Ø200
mm.
Fuel Connection(Gas:300 mbar)
R½"
inch.
Elektr. Connection 380-400/50/3
1,50
kW.
Net Weight
475
kg.
Main Body Dimensions (WXDXH)
Ø62
cm.
Dimensions(W X D X H)
80*125*210
cm.
M300 Specifications
Steam Capacity (Tsu:100°C.)
300
kg/sa.
Steam Heat Power
174.000
kcal/sa.
Steam Heat Power
202
kWh.
Steam Operating Pressure
6,0-8,0
bar.
Burner Power
225-280
kW.
Fuel Consumption(NG-LNG-LPG)
222
kWh.
Unit Water Volume
180
It.
Steam Connection
R1½"
inch.
Exhaust Connection
Ø250
mm.
Fuel Connection(Gas:300 mbar)
R¾"
inch.
Elektr. Connection 380-400/50/3
1,50
kW.
Net Weight
700
kg.
Main Body Dimensions (WXDXH)
Ø73
cm.
Dimensions(W X D X H)
100*155*230
cm.
M600 Specifications
Steam Capacity (Tsu:100°C.)
600
kg/sa.
Steam Heat Power
348.000
kcal/sa.
Steam Heat Power
405
kWh.
Steam Operating Pressure
6,0-8,0
bar.
Burner Power
450-950
kW.
Fuel Consumption(NG-LNG-LPG)
445
kWh.
Unit Water Volume
360
It.
Steam Connection
R2'''
inch.
Exhaust Connection
Ø250
mm.
Fuel Connection(Gas:300 mbar)
R1''
inch.
Elektr. Connection 380-400/50/3
2,50
kW.
Net Weight
1,200
kg.
Main Body Dimensions (WXDXH)
Ø95
cm.
Dimensions(W X D X H)
125*165*240
cm.
M1000 Specifications
Steam Capacity (Tsu:100°C.)
1000
kg/sa.
Steam Heat Power
580.000
kcal/sa.
Steam Heat Power
674
kWh.
Steam Operating Pressure
6,0-8,0
bar.
Burner Power
750-950
kW.
Fuel Consumption(NG-LNG-LPG)
740
kWh.
Unit Water Volume
600
It.
Steam Connection
R2½"
inch.
Exhaust Connection
Ø300
mm.
Fuel Connection(Gas:300 mbar)
R1¼''
inch.
Elektr. Connection 380-400/50/3
3,00
kW.
Net Weight
1.900
kg.
Main Body Dimensions (WXDXH)
Ø116
cm.
Dimensions(W X D X H)
150*185*280
cm.