High Capacity

H - Series

Steam Generators

2.000-4000 kg/h. It is produced in a double serpentine structure with gas and/or liquid fuel at 10-16 bar steam operating pressures. All measurement, control and safety armatures were selected from internationally known brands and almost all of them were backed up. Some technological advantages of the units are summarized below

Heavy Duty Construction, designed with the use of P quality sheet and pipe in accordance with 97/23EC Norms.

Fully Safe Structure with low

Safe Design in which all control elements are used with redundancy (double) for Permak Fail Proof Additional Safety . (Double Mechanical Safety Valve, Dual Pressure Switch, Dual Temperature Transmitter.)

PLC Controlled Full Modulation (1/10-10/10; Burner, External Fan and Pump Controlled) Automatic Operating System where all process parameters can be included in the system with special software.

Proportional Controlled Pneumatic Outlet Valve Module , which protects the Steam Quality, prevents water entrainment and stalling of the generator, and provides full automatic start-stop operations in the units.

PLC Controlled Pneumatic Start Valve Group, which enables the system to enter the automatic regime at the beginning of the job .

Selonoid Valve Grb. which enables automatic (programmable) Bottom Blowdown process at the end of the job.

* Improved Design with Double Main Coil and Additional Flue Gas Line Preheat Coil providing high efficiency . (Efficiency˃91.5% average, Flue Gas Temperature˂250°C, Flue O2˂3.5%, Flue NOx˂60 ppm.)

* Energy Saving and Minimum Thermal Radiation provided by preheating the Combustion Air on the Double Jacketed outer wall . (Thava˃80°C, Yield Increase: +1.6:1.8%.)

Beck Type Burner Group with external fan designed with a special flame length proportional to the combustion chamber and serpentine group for Steam Generators . (Flam)

Additional All Module with quadruple level electrode control, which protects the whole system by constantly measuring the water level and temperature inside the coil.

* Triplex Pump Group, designed as a double unit for high pressure water supply , economically back-up in special cases.

Conductivity Control Module option that measures the Feed Water quality and protects the system under unsuitable conditions.

Compact Electrical Panel where all electrical and electronic elements are selected from internationally known brands (Schneider & Siemens).

* The advantage of supplying and installing a Complete System with Auxiliary Equipment.

(Feedwater Tank, Intermediate Pressure Pump, Water Softening&RO, Flash Steam Exchanger, Dosing Unit, Blowdown Mixer etc.)

“Package System” option where all hardware is mounted in a Platform or Container on demand.

* TÜV, TSEK, Gazmer Quality Certificates. Additional SIL&PL Special Quality Certification option.


Unparalleled Process Monitoring and Ease of Use provided by the use of high-capacity CPU and 7” Touch Screen.
Additional efficiency (1.6-1.8%) increase provided by preheating the combustion air by passing it through the double jacketed body, and Body Heat Loss, which is minimized by the natural insulation feature of the combustion air.
Redundant Control and Protection Armatures for Maximum Safety (Triple Pressostat Group, Double Temperature Probe, Pressure Transmitter, Combustion Cell Thermocouple Controller)ü)
Quintet Coil Design, which increases the heat transfer surface and provides the opportunity to work at Controlled Low Combustion Temperature, Low Flue Temperature and High Efficiency (~93%
True Fully Saturated Steam Quality with independent controls of Steam Temperature and Pressure. (PID Controlled Optimization of Temperature Controlled Pump Flow Rate and Pressure Controlled Burner Flame Amount.)
Possibility of Modulating Operation in the Variable (30-100%) capacity range provided by the Electronic Proportional Control Module.
Super Control Scheme that provides control and monitoring of all process inputs by measuring automatically. (Steam Flow, Water Consumption, Gas Consumption Measurements. Conductivity, Hardness and pH Measurement Control options.)
PLC Controlled Pneumatic Modulation (stroke<3 sec.) Outlet Valve which prevents excessive pressure drop by throttling the line in peak draws.
High Pressure (>30 bar), Triple Cylinder Double Feed Water Pump design that allows the unit to continue operating in case of failure.

H2000 Specifications
Steam Capacity
2.000
kg/sa.
Steam Heat Power
1.160.000
kcal/sa.
Steam Heat Power
1.349
kWh.
Steam Operating Pressure
04-10 (12)
bar.
Burner Power
1500
kW.
Unit Water Volume
240,0
It.
Serpentine Surface
32,0
m².
Fuel Consumption(NG-LNG-LPG)
1.480
kWh.
Fuel Conn. (Gas: 300 mbar)
R2''
inch.
Steam Connection
R2½"
inch.
Exhaust Connection
¢500
mm.
Electricity Connection 380-400/50/3
15,0
kW.
Unit Weight(~)
2.400
kg.
Dimensions(W X D X H)
150*290*180
cm.
H2500 Specifications
Steam Capacity
2.500
kg/sa.
Steam Heat Power
1.450.000
kcal/sa.
Steam Heat Power
1.686
kWh.
Steam Operating Pressure
04-10 (12)
bar.
Brülör Gücü
1.875
kW.
Unit Water Volume
300,0
It.
Serpentine Surface
40,0
m².
Fuel Consumption(NG-LNG-LPG)
1.850
kWh.
Fuel Conn. (Gas: 300 mbar)
R2½"
inch.
Steam Connection
R2½"
inch.
Exhaust Connection
¢500
mm.
Electricity Connection 380-400/50/3
18.0
kW.
Unit Weight(~)
2.900
kg.
Dimensions(W X D X H)
165*320*200
cm.
H3000 Specifications
Steam Capacity
3.000
kg/sa.
Steam Heat Power
1.740.000
kcal/sa.
Steam Heat Power
2.023
kWh.
Steam Operating Pressure
04-10 (12)
bar.
Burner Power
2.250
kW.
Unit Water Volume
360,0
It.
Serpentine Surface
48,0
m².
Fuel Consumption(NG-LNG-LPG)
2.220
kWh.
Fuel Conn. (Gas: 300 mbar)
R3''
inch.
Steam Connection
R3''
inch.
Exhaust Connection
¢600
mm.
Electricity Connection 380-400/50/3
21,0
kW.
Unit Weight(~)
3.400
kg.
Dimensions(W X D X H)
180*320*220
cm.
H3500 Specifications
Steam Capacity
3.500
kg/sa.
Steam Heat Power
2.030.000
kcal/sa.
Steam Heat Power
2.360
kWh.
Steam Operating Pressure
04-10 (12)
bar.
Burner Power
2.625
kW.
Unit Water Volume
420,0
It.
Serpentine Surface
56,0
m².
Fuel Consumption(NG-LNG-LPG)
2.590
kWh.
Fuel Conn. (Gas: 300 mbar)
R4''
inch.
Steam Connection
R4''
inch.
Exhaust Connection
¢600
mm.
Electricity Connection 380-400/50/3
24,0
kW.
Unit Weight(~)
3.950
kg.
Dimensions(W X D X H)
210*320*260
cm.
H4000 Specifications
Steam Capacity
4.000
kg/sa.
Steam Heat Power
2.320.000
kcal/sa.
Steam Heat Power
2.698
kWh.
Steam Operating Pressure
04-10 (12)
bar.
Burner Power
3.000
kW.
Unit Water Volume
480,0
It.
Serpentine Surface
64,0
m².
Fuel Consumption(NG-LNG-LPG)
2.960
kWh.
Fuel Conn. (Gas: 300 mbar)
R4''
inch.
Steam Connection
R4''
inch.
Exhaust Connection
¢600
mm.
Electricity Connection 380-400/50/3
27,0
kW.
Unit Weight(~)
4.450
kg.
Dimensions(W X D X H)
210*360*260
cm.